The battery pack service terminal maintenance tester (BST-DW series) performs capacity verification, SOC adjustment, fault diagnosis, and maintenance for new energy vehicle battery packs at service terminals (service stations), and complies with terminal service processes to generate data and related test reports. The maintenance tester is a low-cost, highly integrated intelligent device developed for service terminal scenarios that can be expanded and uploaded to the cloud, thereby reducing the operating costs of the service terminal and the reliance on the skills and responsibility of the operating technicians, while ensuring the consistency and integrity of the maintenance service quality.
Multiple compatibility – Supports multiple models of battery pack SN information entry to meet the diverse needs of different customers.
Intelligent scanning – Use wireless method to quickly scan the battery pack SN code, and automatically match the best test plan to simplify the operation process.
Independent channel – It has 1 high-voltage and 1 low-voltage charging and discharging channel, and the channels can operate independently without affecting each other.
Multi-level protection – Supports two-level charging and discharging software protection for process steps and global, and hardware protection for battery pack reverse connection, wrong connection, missing connection, overcurrent, etc., making the equipment operation safer.
Cut-off condition – Supports multiple charging and discharging cut-off condition settings, including total voltage, SOC, capacity, running time, single cell voltage, battery temperature, etc.
Abnormal relay – Supports the function of abnormal interruption and continuation of project plan operation to eliminate invalid work.
Multiple modes – Supports automatic and manual test functions, and operators can switch freely to adapt to more application scenarios.
Power-off protection – Supports automatic data saving and shutdown of the equipment after abnormal AC power failure.
Data archiving – Supports query, export and generation of test reports for historical operation data.
Report generation – Automatically generate report files containing all relevant historical test data, and can be directly exported to files.
Permission control – Set operator access rights to enhance the security and privacy protection of equipment use.
Brand: Guheng Energy | Input voltage: 380Vac | Output channels: 2 (high voltage/low voltage) | High voltage channel voltage range: 150~1000V |
High voltage channel charge and discharge current: 2~120A | High voltage channel charging and discharging power: 60KW | Low voltage channel voltage range: 5~200V | Low voltage channel charging current: 2~60A |
Low voltage channel discharge current: 2~100A | Low voltage channel charging and discharging power: 6KW | Place of shipment: Hangzhou |
The battery pack service terminal maintenance tester (BST-DW series) performs capacity verification, SOC adjustment, fault diagnosis, and maintenance for new energy vehicle battery packs at service terminals (service stations), and complies with terminal service processes to generate data and related test reports. The maintenance tester is a low-cost, highly integrated intelligent device developed for service terminal scenarios that can be expanded and uploaded to the cloud, thereby reducing the operating costs of the service terminal and the reliance on the skills and responsibility of the operating technicians, while ensuring the consistency and integrity of the maintenance service quality.
Multiple compatibility – Supports multiple models of battery pack SN information entry to meet the diverse needs of different customers.
Intelligent scanning – Use wireless method to quickly scan the battery pack SN code, and automatically match the best test plan to simplify the operation process.
Independent channel – It has 1 high-voltage and 1 low-voltage charging and discharging channel, and the channels can operate independently without affecting each other.
Multi-level protection – Supports two-level charging and discharging software protection for process steps and global, and hardware protection for battery pack reverse connection, wrong connection, missing connection, overcurrent, etc., making the equipment operation safer.
Cut-off condition – Supports multiple charging and discharging cut-off condition settings, including total voltage, SOC, capacity, running time, single cell voltage, battery temperature, etc.
Abnormal relay – Supports the function of abnormal interruption and continuation of project plan operation to eliminate invalid work.
Multiple modes – Supports automatic and manual test functions, and operators can switch freely to adapt to more application scenarios.
Power-off protection – Supports automatic data saving and shutdown of the equipment after abnormal AC power failure.
Data archiving – Supports query, export and generation of test reports for historical operation data.
Report generation – Automatically generate report files containing all relevant historical test data, and can be directly exported to files.
Permission control – Set operator access rights to enhance the security and privacy protection of equipment use.
Brand: Guheng Energy | Input voltage: 380Vac | Output channels: 2 (high voltage/low voltage) | High voltage channel voltage range: 150~1000V |
High voltage channel charge and discharge current: 2~120A | High voltage channel charging and discharging power: 60KW | Low voltage channel voltage range: 5~200V | Low voltage channel charging current: 2~60A |
Low voltage channel discharge current: 2~100A | Low voltage channel charging and discharging power: 6KW | Place of shipment: Hangzhou |